Advanced lluminated Pulsar 710 Manual del operador Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
a d v a n c e d i l l u m i n a t i o n . c o m
P u l s a r 7 1 0 M a n u a l
3.2.3 Red: The red light blinks an error
code in the case of an error condition.
The condition is indicated by three sets
of sequential ashes. For example: 4
ashesfollowedby2ashesfollowedby
3ashesindicatesanerrorcodeof423
whichsigniesthatthemainpowerswitch
is off. Two common error codes are:
• 351: No light head detected.
• 423: The main power switch is off.
(Refer to section 6.0 “Troubleshooting” for more detailed error code
information.)
3.3 Local Control
For the purposes of this procedure, the Pulsar 710 will be operated in self
testmodeutilizinglocalcontrol.
Using Figure 1, locate the four section dip switch that sets the operating
mode of the Pulsar 710. Set the four switches to 1110, from left to
right. Logic “1” is set when the switch is up and logic “0” when the
switch is down. This is Mode 14 and enables an internal trigger having a
repetitionrateof10Hz.Thepulsewidthissetbythethree10position
rotary switches at the far left of the front panel. The rotary switches set
the pulse width in microseconds, up to 999 microseconds. A reasonable
starting pulse width for testing is 20 microseconds. Example: Set the
“10’s” switch to “2”, leaving the “100’s” and “1’s” switches set to “0”.
Set the power switch to “on”. The selected mode is activated by the
Pulsar 710 when the power is applied or when the light head is changed.
Assuming that the connected light headiscongured with one ofAi’s
two Signatech options, the Pulsar 710 will set a safe current level for
the light head based on the repetition rate and the pulse width. Older
light head’s without Signatech will cause the Pulsar 710 to shut down
and ash error code 352 (See chapter 6.0 “troubleshooting” for a
complete listing of trouble codes). The pulse width may now be varied
using the three rotary switches. Successful operation in this mode
indicates that the Pulsar 710 and light head are functioning correctly.
10
Figure 4: Status indicator Lights